Electrical and Electronics Instrument
TEMS System for Electrical and Electronics Instrument Measuring System
InquiryEMI Measuring System
Radiated Emission |
Measuring Radiated Emission using Broad band Antenna Measuring Environment: Anechoic Chamber/Open Area Test Site Frequency Range : 30MHz-3GHz Applicable Standard: CISPR/FCC /VCCI /EN55022/EN55011 [Option: CISPR25, 95/54/EC] |
---|---|
Conducted Emission |
Measuring Conducted Emission using LISN Measuring Environment: Shielded Room Frequency Range : 9kHz-30MHz Applicable Standard: CISPR/FCC /VCCI /EN55022/EN55011/EN55014/Radio Regulation Law and so on [Option: CISPR25] |
Microwave Radiation Immunity Measurement |
Measuring Radiated Emission using Horn Antenna Measuring Environment: Anechoic Chamber Frequency Range : 1GHz-40GHz Applicable Standard: CISPR/FCC |
Interference Power (Clamp Method) |
Using Absorbing Clamp and measuring leakage current from a cable which is connecting with EUT Measuring Environment: Shielded Room Frequency Range : 30MHz-300MHz Applicable Standard: CISPR/Radio Regulation Law and so on |
Magnetic Field Strength |
Measuring Radiated Emission using Loop Antenna Measuring Environment: Shielded Room Frequency Range : 9kHz-30MHz Applicable Standard: EN55011/FCC P18 and so on |
Electric Field Strength |
Measuring Radiated Emission in the Shielded Room using Rod Antenna. Measuring Environment: Shielded Room Frequency Range : 9kHz-30MHz Applicable Standard: [Option: CISPR25] |
Site Attenuation |
EMC Compatibility Measuring Services of Anechoic Chamber for EMI Measurement Measuring Environment: Anechoic Chamber Frequency Range : 30MHz-1GHz Applicable Standard: ANSI C63.4 |
Site Attenuation for Dipole |
EMC Compatibility Measuring Services of Anechoic Chamber for EMI Measurement using Dipole Antenna Frequency Range : 30MHz-1GHz Applicable Standard: ANSI C63.4, VCCI Technical Standard |
Cable loss |
Measuring a cable loss for EMI Measurement Result can be used in EMI Measurement Frequency Range: 30MHz-1GHz |
EMS Test System
Radiated Immunity |
Measuring Immunity by applying Electric current Measuring Environment: Anechoic Chamber Frequency Range: 26MHz-40GHz Applicable Standard: IEC61000-4-3 and so on |
---|---|
Conducted Immunity |
Measuring Immunity by applying Electric current to a cable of EUT Measuring Environment: Anechoic Chamber Frequency Range: 150kHz – 230MHz Applicable Standard: IEC61000-4-6 and so on |
Electric Field Uniformity |
Automatic determination of Electric Field uniformity by measuring 16 points in an Anechoic chamber for Radiated Immunity test. Frequency Range: 26MHz-1GHz Applicable Standard: JEIDA-52-1998, IEC61000-4-3 and so on |